Mfg Part Number: 5114-1803-1 | Alternate P/N: 511418031 | NSN : 5925-01-336-6383 |
NIIN : 013366383 | CAGE Code : 29957 | Manufacturer: Nordam Group Inc |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Integrated AOG is your sourcing solution for all your NSN part 5114-1803-1 under 5925 Circuit Breakers needs, presenting NSN 5925-01-336-6383 by Nordam Group Inc at competitive prices. This Circuit Breaker NSN item is listed alongside the part number 5114-1803-1, and it is readily available for purchase from our website at any time. If you would like to learn more about this item and receive a customized quote for your comparisons, fill out and submit an RFQ form as provided on our website at your earliest convenience. Please be sure to let us know details such as your target price and expected shipping time as this will allow us to tailor the best solution for your needs. With team members available for customer needs around the clock, we promise responses to quote requests within 15 minutes of receiving a completed form.
With our utmost dedication to quality, we proudly operate as an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise. All of our items are sourced from leading manufacturers we trust like Nordam Group Inc, and countless products are subjected to rigorous quality control measures prior to shipment. Additionally, we ensure that customers only procure the exact items that they need by listing products alongside various related details, such as this part being specifically produced under the CAGE Code 29957. Get in touch with an Integrated AOG team member today to begin the purchasing process for part number 5114-1803-1, and see why customers choose to steadily rely on us for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-336-6383 Item Description: Circuit Breaker | 5925 | 013366383 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5114-1803-1 | 5 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.937 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AEFN | NONTURN DEVICE LOCATION | AT 3 OCLOCK AND AT 9 OCLOCK |
AEFQ | NONTURN DEVICE LENGTH | 0.005 INCHES MINIMUM AND 0.015 INCHES MAXIMUM |
AEFS | NONTURN DEVICE DIAMETER | 0.250 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBME | III CUBIC MEASURE | 8.941 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ZZZK | SPECIFICATION/STANDARD DATA | 29957-5114-1803 MANUFACTURERS SPECIFICATION CONTROL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
AKPX | POLE QUANTITY | 3 |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
ADTV | CASE MATERIAL | METAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT AND HERMETICALLY SEALED |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.