Mfg Part Number: PM40 | NSN : 5925-00-175-5197 | NIIN : 001755197 |
CAGE Code : 82647 | Manufacturer: Sensata Technologies Inc | Item Name : Circuit Breaker |
FSC : 5925 Circuit Breakers |
Integrated AOG is your sourcing solution for all your NSN part PM40 under 5925 Circuit Breakers needs, presenting NSN 5925-00-175-5197 by Sensata Technologies Inc at competitive prices. This Circuit Breaker NSN item is listed alongside the part number PM40, and it is readily available for purchase from our website at any time. If you would like to learn more about this item and receive a customized quote for your comparisons, fill out and submit an RFQ form as provided on our website at your earliest convenience. Please be sure to let us know details such as your target price and expected shipping time as this will allow us to tailor the best solution for your needs. With team members available for customer needs around the clock, we promise responses to quote requests within 15 minutes of receiving a completed form.
With our utmost dedication to quality, we proudly operate as an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise. All of our items are sourced from leading manufacturers we trust like Sensata Technologies Inc, and countless products are subjected to rigorous quality control measures prior to shipment. Additionally, we ensure that customers only procure the exact items that they need by listing products alongside various related details, such as this part being specifically produced under the CAGE Code 82647. Get in touch with an Integrated AOG team member today to begin the purchasing process for part number PM40, and see why customers choose to steadily rely on us for all their operational needs.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2 000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1 531 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1 188 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0 188 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40 0 AMPERES AC AND 40 0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30 0 AC AND 30 0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 800 0 AC AND 800 0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 120 0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 PUSH BUTTON |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 100 000 NOMINAL AT 125 PCT AND 7 000 NOMINAL AT 200 PCT AND 1 800 NOMINAL AT 300 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25 0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CWJK | CASE MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
![]() |