Thank you for your continued interest in sourcing the NSN 5950-01-339-8204 (Transformer Assembl) components you require from Integrated AOG. Below, you may locate all items with the NSN 5950-01-339-8204, including in-demand part numbers like 10132963, 12020-1, 321 18050 05, 984882-5B, and more! As an ASAP Semiconductor owned and operated purchasing platform, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, in tandem with a strict No China Sourcing pledge. This allows us to ensure all products in our inventory of over 2 billion parts are vetted for fit and function before shipment to you, alongside their applicable trace documentation. To begin procuring any of the NSN 5950-01-339-8204 parts from Paaesikunta Logistiikkaosasto, Sora Power Inc, Oeco Corp, Raytheon Company, simply fill out and submit a Request for Quote (RFQ) form outlining any pertinent details regarding your part needs, and we will provide you with a competitive quote within 15 minutes or less. Offering rapid lead times and competitive pricing, find out why loyal customers rely on us time and time again. To learn more, contact us at any time via phone or email.
Item Name | Transformer Assembl |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
NIIN | 01-339-8204 (013398204) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
10132963 | paaesikunta logistiikkaosasto | transformer assembl | Avl | RFQ |
12020-1 | sora power inc | transformer assembl | Avl | RFQ |
321 18050 05 | oeco corp | transformer assembl | Avl | RFQ |
984882-5B | raytheon company | transformer assembl | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.030 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 3.570 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT |
ADAT | BODY WIDTH | 3.440 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 3RD SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CRBZ | WINDING OPERATING CURRENT | 0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.280 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 12.000 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
AFHM | MOUNTING TAB WIDTH | 0.625 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 1ST GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AXGY | MOUNTING METHOD | TAB 3RD GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 1ST SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.090 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 1.200 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.750 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 36 WIRE LEAD |
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) |
Low Price Warrantied inventory at competitive prices
Get it fast All inventory ready to ship from our sellers
Find it fast Search the world’s largest inventory of electronic components by manufacturer, category or part number
Quality guaranteed We sell only warrantied and traceable parts
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote