Mfg Part Number: 321 18050 05 | Alternate P/N: 3211805005 | NSN : 5950-01-339-8204 |
NIIN : 013398204 | CAGE Code : 95266 | Manufacturer: Oeco Corp |
Item Name : Transformer Assembl | FSC : 5950 Coils and Transformers |
Integrated AOG is your sourcing solution for all your NSN part 321 18050 05 under 5950 Coils and Transformers needs, presenting NSN 5950-01-339-8204 by Oeco Corp at competitive prices. This Transformer Assembl NSN item is listed alongside the part number 321 18050 05, and it is readily available for purchase from our website at any time. If you would like to learn more about this item and receive a customized quote for your comparisons, fill out and submit an RFQ form as provided on our website at your earliest convenience. Please be sure to let us know details such as your target price and expected shipping time as this will allow us to tailor the best solution for your needs. With team members available for customer needs around the clock, we promise responses to quote requests within 15 minutes of receiving a completed form.
With our utmost dedication to quality, we proudly operate as an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise. All of our items are sourced from leading manufacturers we trust like Oeco Corp, and countless products are subjected to rigorous quality control measures prior to shipment. Additionally, we ensure that customers only procure the exact items that they need by listing products alongside various related details, such as this part being specifically produced under the CAGE Code 95266. Get in touch with an Integrated AOG team member today to begin the purchasing process for part number 321 18050 05, and see why customers choose to steadily rely on us for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-339-8204 Item Description: TRANSFORMER ASSEMBLY | 5950 | 013398204 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10132963 | 5 | 9 | 6 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.030 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 3.570 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT |
ADAT | BODY WIDTH | 3.440 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 3RD SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CRBZ | WINDING OPERATING CURRENT | 0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.280 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 12.000 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
AFHM | MOUNTING TAB WIDTH | 0.625 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 1ST GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AXGY | MOUNTING METHOD | TAB 3RD GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 1ST SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.090 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 1.200 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.750 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 36 WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote